CJFQJ - RTV 133 SILICONE SEALANT
- MSDS: CJFQJ
- Manufacturer: GENERAL ELECTRIC CO SILICONE PRODUCTS DIV
- Product Name: RTV 133 SILICONE SEALANT
- National Stock Number: 8040-01-168-0077
Product Identification
Product ID:RTV 133 SILICONE SEALANT
MSDS Date:06/11/1997
FSC:8040
NIIN:01-168-0077
Status Code:A
MSDS Number: CJFQJ
Responsible Party
WATERFORD, NY 12188
Emergency Phone: 518-237-3330
Info Phone: 518-237-3330
Preparer: CE HANNIGAN
Cage: 01139
Contractor
Telephone: 518-237-3330/800-332-3390
Cage: 01139
Ingredients
VINYLTRIMETHOXYSILANE
CAS: 2768-02-7
RTECS: VV6770000
TITANIUM, BIS(ETHYL ACETOACETATO)-DIISOPROPOXY
CAS: 27858-32-8
VINYLSTOPPED PHENYLMETHYL POLYMER
CAS: 68951-96-2
DIMETHYL POLYSILOXANE SILANOL/ST
CAS: 70131-67-8
D4 & HMDZ TREATED SILICON DIOXIDE
CAS: 68937-51-9
OSHA PEL 15 MG/M3
ACGIH TLV: 10 MG/M3
QUARTZ
CAS: 14808-60-7
RTECS: VV7330000
OSHA PEL 0.1 MG/M3 TWA
ACGIH TLV: 0.1 MG/M3
Hazards
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY BE HARMFUL IF SWALLOWED. UNCURED
PRODUCT CONTACT WILL IRRITATE LIPS, GUMS, TONGUE AND SKIN. CAUSES
MILD RESPIRATORY IRRITATION. CAUSES EYE IRRITATION.
Effects of Overexposure:METHANOL RELEASED DURING CURING. THIS PRODUCT
CONTAINS METHYLPOLYSILOXANES WHICH CAN GENERATE FORMALDEHYDE AT
APPROX 300 F. FORMALDEHYDE IS A SKIN AND RESPIRATORY SENSITIZER,
EYE AND THROAT IRRITANT, ACUTE TOXICANT, AND POTENTIAL CANCER
HAZARD. AN MSDS FOR FORMALDEHYDE IS AVAILABLE FROM GE SILICONES.
Medical Cond Aggravated by Exposure:NONE KNOWN
First Aid
First Aid:EYES:IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR 15 MINUTES.IF
IRRITATION PERSISTS,SEE DOCTOR;SKIN:REMOVE COMPLETELY WITH A DRY
CLOTH OR PAPER TOWEL,BEFORE WASHING WITH DETERGENT & WATER;
INHALATION: R EMOVE TO FRESH AIR;INGESTION:SEE DOCTOR. INGEST:
RINSE MOUTH WITH WATER SEVERAL TIMES.
Fire Fighting
Extinguishing Media:ALL STANDARD FIRE FIGHTING MEDIA
Fire Fighting Procedures:NONE KNOWN
Unusual Fire/Explosion Hazard:NONE
Accidental Release
Spill Release Procedures:WIPE,SCRAPE OR SOAK UP IN AN INERT MATERIAL &
PUT IN A CONTAINER FOR DISPOSAL. WASH WALKING SURFACES WITH
DETERGENT & WATER TO REDUCE SLIPPING HAZARD. WEAR PROPER PROTECTIVE
EQUIPMENT.
Handling
Handling and Storage Precautions:USE IN WELL VENTILATED AREA. REMOVE
CONTACT LENSES BEFORE HANDLING SEALANT. DO NOT HANDLE LENSES UNTIL
ALL SEALANT HAS BEEN CLEANED FROM FINGERTIPS, NAILS, AND CUTICLES.
RESIDUAL SEALLANT MAY REMAIN O N FINGERS FOR SEVERAL DAYS AND
TRANSFER TO LENSES CAUSING SEVERE EYE IRRITATION.
Other Precautions:PRODUCT RELEASES METHANOL DURING APPLICATION AND
CURING (METHANOL TLV=200 PPM).
Exposure Controls
Respiratory Protection:USE ONLY IN A WELL VENTILATED AREA
Ventilation:USE ONLY IN A WELL VENTILATED AREA
Protective Gloves:CLOTH
Eye Protection:SAFETY GLASSES
Other Protective Equipment:EYEWASH STATION
Supplemental Safety and Health
Chemical Properties
Spec Gravity:1.23 WATER=1
VOC Pounds/Gallon:60
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BLACK SOLID, SWEET ODOR.
Percent Volatiles by Volume:<4.9
Stability
Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:NONE KNOWN
Hazardous Decomposition Products:CO,CO*2,SIO*2. METHANOL, FORMALDEHYDE
Disposal
Waste Disposal Methods:DISPOSE OF IN COMPLIANCE WITH ALL FEDERAL,STATE
& LOCAL REGULATIONS.
Regulatory
SARA Title III Information:SARA 311, 312 HAZARD CLASS: ACUTE HEALTH
HAZARD
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.